| Eprom
Programming RCA CTC175 thru 177 |
1: Turn set on by Pressing and releasing the Power
Button.
2: How to Enter the Service Menu :
A: Press and hold the "MENU" button.
B: Press and release the "POWER" button.
C: Press and release the "VOL+" button.
D: Realease the "MENU" button.
A parameter number or "P00" should appear on the left side of the TV's
CRT screen. A currentadjustment value or "V))" should appear on the
right side of the display.
3: Press the "VOL+" button until the "V00" is "V76"
Press the "CH+" button to move to "P01"
You are know set to adjust your first parameter the Horizontal Freqency.
The range of this adjustment is from "V00" to "V63".
Use the "VOL+" and "VOL-" buttons to change "V00" value.
Use the "CH+" button to move to the next parameter you need to adjust.
When you are finished with the set up press the "POWER" button to exit.
|
Service
Adjustment Parameters |
| Alignment
Parameter "P" |
Description
of Parameter |
Value
Range |
| P01 |
Horiz. Frequency |
00 - 63 |
| P02 |
Horiz Phase |
00 - 15 |
| P03 |
Horiz. Width |
00 - 15 |
| P04 |
Pincussion Amp |
00 - 07 |
| P05 |
Vertical Center |
00 - 15 |
| P06 |
Vertical Height |
00 - 31 |
| P07 |
Red Bias |
00 - 127 |
| P08 |
Green Bias |
00 - 127 |
| P09 |
Blue Bias |
00 - 127 |
| P10 |
Red Drive |
00 - 63 |
| P11 |
Green Drive |
00 - 63 |
| P12 |
Blue Drive |
00 - 63 |
| P13 |
Security Pass |
#77 |
| |
|
|
|
|