The
PROBE60S, PROBE100 and PROB150 are passive high
impedance oscilloscope probes designed and calibrated
for use on instruments having an input impedance
of 1M ohm shunted by 25pf. However it may be compensated
for use with instruments having an input capacity
of 10-35pf.
The probes incorporate a two position slide switch
on the body which selects attenuation of X1, X10
positions. |
|
Features
Complete probe set
insulated for hand-held equipment - IEC1010
attenuation : 1:1 or 1:10
Specifications
position x1 :
attenuation : 1:1
bandwidth : DC to 15MHz
rise time : 2.7ns
input resistance : 1Mohm (input resistance scope)
input capacitance : 46pF + cap. scope
working voltage : 600V DC incl. peak AC derating with
frequency
position REF : -
position x10 :
attenuation : 1:10
bandwidth : DC to 60MHz
rise time : 5.5ns
input resistance : 10Mohm (if scope input = 1Mohm)
input capacitance : 18pF approx.
working voltage : 600V DC incl. peak AC derating with
frequency
compensation range : 10 to 35pF
cable length : 4.6ft
remarks : with insulated BNC connector
$16.95 each $
152.50/10
|
Features
Complete probe set, for measurements
up to 100MHz
attenuation : 1:1 or 1:10
Specifications
position x1 :
attenuation : 1:1
bandwidth : DC to 60MHz
rise time : 5.8ns
input resistance : 1Mohm (input resistance scope)
input capacitance : 90pF + cap. scope
working voltage : 600V DC incl. peak AC derating with
frequency
position REF : tip disconnected, scope input at ground
position x10 :
attenuation : 1:10
bandwidth : DC to 100MHz
rise time : 2.8ns
input resistance : 10Mohm (if scope input = 1Mohm)
input capacitance : 16pF approx.
working voltage : 600V DC incl. peak AC derating with
frequency
compensation range : 10 to 35pF
cable length : 4.6ft
$ 35.00 each
|
Features
Complete probe set, for measurements
up to 150MHz
attenuation : 1:1 or 1:10
Specifications
position x1 :
attenuation : 1:1
bandwidth : DC to 60MHz
rise time : 5.8ns
input resistance : 1Mohm (input resistance scope)
input capacitance : 90pF + cap. scope
working voltage : 600V DC incl. peak AC derating with
frequency
position REF : tip disconnected, scope input at ground
position x10 :
attenuation : 1:10
bandwidth : DC to 150MHz
rise time : 1.4ns
input resistance : 10Mohm (if scope input = 1Mohm)
input capacitance : 15pF approx.
working voltage : 600V DC incl. peak AC derating with
frequency
compensation range : 10 to 35pF
cable length : 3.9ft
$ 49.95 each
|
|