| DELAY ON RELEASE - Input voltage must be applied continuously to operate the internal relay. When the control switch is closed, the relay energizes. When the control switch is opened, timing begins. When timing is complete, the relay will de-energize. Time may be reset to zero during timing by closing the control switch. |
 |
| DPDT, 2 Form "C" |
 |
| NTE Type No. |
Nom. Volt. |
Contact Arr. |
Input Cur. Nom. |
Max. Contact Cur, @ 28VDC or 120VAC |
Diag. No. |
| AC OPERATED |
| R36-11A12-120K |
120VAC |
DPDT |
20mA |
12A |
D18a |
| R36-11A12-120L |
120VAC |
DPDT |
20mA |
12A |
D18a |
| ACCESSORIES |
| Mounting Styles |
Description |
NTE Type No. |
| Surface Mount |
11-Pin Blade |
R95-105 |
| Panel Mount, Solder Terminal |
11-Pin Blade |
R95-116 |
| Panel Mount, Quick Connect |
11-Pin Blade |
R95-124 |
| DIN Rail Mount |
11-Pin Blade |
R95-115 |
| PC Mount |
11-Pin Blade |
R95-123 |
|
Dimensional DrawingD18a
Electrical Specifications
Contact
Rating: 12 Amps 120 VAC, 28 VDC Resistive, 1/2 HP @ 240 VAC, 1/3 HP @ 120 VAC
Life: 300,000 operations @ 120 VAC, 12A resistive 5,000,000 operations @ 32 VDC, 5A resistive
Input
Nominal Input Voltages: 120 VAC
Steady State Input Current: 20mA @ 120 VAC
Timing
Timing Adjustment Modes Available: 0.1 to 10 sec (K-suffix) 1.0 to 180 sec (L-suffix)
Repeat Accuracy
±0.1% ±33mS AC constant voltage & temperature
Percent Timing Range over Temperature & Voltage Range: ±10%
Timing Tolerance at High End of Range: -0, +40%
Timing Tolerance at Low End of Range: +0, -40%
Reset Time: 100mS Max
Protection
Transient: Twice normal for 1mS
Dielectric Breakdown:
Coil To Contact: 2000 VAC
Across Open Contact: 1000 VAC
Environmental Characteristics
Operating: -10°C to +55°C Storage: -55°C to +85°C
Weight
Std: 4 ozs. (96 grams) - approx |