| DELAY ON RELEASE - Input voltage must be applied continuously to operate the internal relay. When the control switch is closed, the relay energizes. When the control switch is opened, timing begins. When timing is complete, the relay will de-energize. Time may be reset to zero during timing by closing the control switch. |
 |
| DPDT, 2 Form "C" |
 |
| NTE Type No. |
Nom. Volt. |
Contact Arr. |
Input Cur. Nom. |
Max. Contact Cur, @ 28VDC or 120VAC |
Diag. No. |
| AC OPERATED |
| R32-11A10-10K |
120VAC |
DPDT |
20mA |
10A |
D17 |
| R32-11A10-120L |
120VAC |
DPDT |
20mA |
10A |
D17 |
| R32-11A10-120M |
120VAC |
DPDT |
20mA |
10A |
D17 |
| DC OPERATED |
| R32-11D10-24K |
24VDC |
DPDT |
40mA |
10A |
D17 |
| R32-11D10-24L |
24VDC |
DPDT |
40mA |
10A |
D17 |
| ACCESSORIES |
| Mounting Styles |
Description |
NTE Type No. |
| Surface Mount |
11-Pin Octal |
R95-104 |
| Panel Mount |
11-Pin Octal |
R95-119 |
| DIN Rail Mount |
11-Pin Octal |
R95-114 |
| 11-Pin Octal |
R95-182 |
|
|
Dimensional DrawingD17
Electrical Specifications
Contact
Rating: 10 Amps 120 VAC, 30 VDC-8 Amp, 1/2 HP @ 240 VAC, 1/3 HP @ 120 VAC
Life: 500,000 operations @ 120 VAC, 10A resistive 1,000,000 operations @ 120 VAC, 5A resistive 2,000,000 operations @ 120 VAC, 2A resistive
Mechanical Life: 50,000,000 operations
Input
Nominal Input Voltages: See Chart
Steady State Input Current: See Chart
Timing
Timing Adjustment Modes Available: 0.1 to 10 sec (K-suffix) 1.0 to 180 sec (L-suffix) 2.0 to 300 sec (M-suffix)
Repeat Accuracy
±0.1% - constant voltage & temperature
Percent Timing Range over Temperature & Voltage Range: ±10%
Timing Tolerance at High End of Range: -0, +40%
Timing Tolerance at Low End of Range: +0, -40%
Reset Time: 100mS Max
Protection
Transient: UL508 surge test 5000V for 50mS
Dielectric Breakdown:
Coil To Contact: 1500 VAC
Across Open Contact: 1000 VAC
Noise Immunity: NEMA ICS 2-230 2500 VAC
Environmental Characteristics
Operating: -10°C to +55°C Storage: -55°C to +85°C
Weight
Std: 4 ozs. (115 grams) - approx |