Features Screw terminalsLong life contactsMolded plastic barrier insulationMolded nylon bobbin coilRED indicates new device |
R04 Series |
 |
|
Heavy Duty, 30 Amp, open frame relays designed for industrial control, high inrush current applications such as motor starting and incandecent lamp loads |
|
| AC OPERATED |
| NTE Type No. |
Nom. Voltage |
Contact Arr. |
Coil Res. Ohms (Typ) |
Nom. Power |
Max. Contact Cur. @ 28VDC or 120VAC |
Diag. No. |
| R04-3A30-12 |
12VAC |
SPST-NO |
- |
10VA |
30A |
D4 |
| R04-3A30-24 |
24VAC |
SPST-NO |
- |
10VA |
30A |
D4 |
| R04-3A30-120 |
120VAC |
SPST-NO |
- |
10VA |
30A |
D4 |
| R04-3A30-240 |
240VAC |
SPST-NO |
- |
10VA |
30A |
D4 |
| R04-5A30-12 |
12VAC |
SPDT |
- |
10VA |
30A |
D3 |
| R04-5A30-24 |
24VAC |
SPDT |
- |
10VA |
30A |
D3 |
| R04-5A30-110 |
110VAC |
SPDT |
- |
10VA |
30A |
D3 |
| R04-5A30-240 |
240VAC |
SPDT |
- |
10VA |
30A |
D3 |
| R04-7A30-12 |
12VAC |
DPST-NO |
- |
10VA |
30A |
D4 |
| R04-7A30-24 |
24VAC |
DPST-NO |
- |
10VA |
30A |
D4 |
| R04-7A30-120 |
120VAC |
DPST-NO |
- |
10VA |
30A |
D4 |
| R04-7A30-240 |
240VAC |
DPST-NO |
- |
10VA |
30A |
D3 |
| R04-11A30-12 |
12VAC |
DPDT |
- |
10VA |
30A |
D5 |
| R04-11A30-24 |
24VAC |
DPDT |
- |
10VA |
30A |
D5 |
| R04-11A30-120 |
120VAC |
DPDT |
- |
10VA |
30A |
D5 |
| R04-11A30-240 |
240VAC |
DPDT |
- |
10VA |
30A |
D5 |
| DC OPERATED |
| R04-3D30-12 |
12VDC |
SPST-NO |
70 |
2.0W |
30A |
D4 |
| R04-3D30-24 |
24VDC |
SPST-NO |
290 |
2.0W |
30A |
D4 |
| R04-5D30-12 |
12VDC |
SPDT |
70 |
2.0W |
30A |
D3 |
| R04-5D30-24 |
24VDC |
SPDT |
290 |
2.0W |
30A |
D3 |
| R04-5D30-110 |
110VDC |
SPDT |
6K |
2.0W |
30A |
D3 |
| R04-7D30-12 |
12VDC |
DPST-NO |
70 |
2.0W |
30A |
D4 |
| R04-7D30-24 |
24VDC |
DPST-NO |
290 |
2.0W |
30A |
D4 |
| R04-7D30-110 |
110VDC |
DPST-NO |
6K |
2.0W |
30A |
D4 |
| R04-11D30-12 |
12VDC |
DPDT |
70 |
2.0W |
30A |
D5 |
| R04-11D30-24 |
24VDC |
DPDT |
290 |
2.0W |
30A |
D5 |
| R04-11D30-48 |
48VDC |
DPDT |
1200 |
2.0W |
30A |
D5 |
| R04-11D30-110 |
110VDC |
DPDT |
6K |
2.0W |
30A |
D5 |
|
Electrical Specifications
Contact
Contact Rating: 30 Amps up to 300VAC, 50/60Hz, 5 Amps @ 480/600VAC, 50/60Hz, 0.75pF (slightly inductive) load. 1 1/2 HP motor load at 120 thru 600VAC, 50/60Hz. 30 Amps @ 28VDC, resistive load (each pole). 2 HP motor load at 200 thru 600VAC, 50/60Hz when using two poles to switch both sides of load.
Contact Material: Silver cadmium oxide, 5/16" Dia.
Coil
Coil Voltages: See Chart
Coil Resistance: See Chart
Coil Power: Maximum Coil Dissipation: 4 Watts DC
Duty Cycle: Continuous
Operational Characteristics
Timing Values:
Operate Time: 40mS or less
Release Time: 30mS or less
Insulation Characteristics
Dielectric Strength:
Across Open Contacts: 1500 VRMS
Between mutually insulated conductive
elements: 2200 VRMS
Environmental Characteristics
Operating: -30°C to +50°C (AC)
Operating: -30°C to +60°C (DC)
Non-operating (storage): -30°C to +100°C
Weight
D3 style case: 8 ozs. (227 grams) - Approx
D4 style case: 9 ozs. (255 grams) - Approx
D5 style case: 11 ozs. (311 grams) - Approx |
|